Models. Contents.
Semiconductor Development Kits (4377) Sensor ICs (1931) Standard Logic (7992). Pulsar evolution UPS,2200VA RS Stock No. 425-1088; Mfr. Quick Start Guide 2200/3000/3000XL UPS. Installatie- en gebruikershandleiding. Manuel d'insallation et d'utilisation. 2200/3000/3000XL UPS User Manual. Safety Instructions.
Read before installing product. MGE UPS Systems. Using this document. Pictograms.
1. Presentation.
5. Environment. 2. Installation. 3. Operation. 4.
Maintenance. 6. Appendices. Tower position. Rack position. Pulsar Evolution 3000 / 3000 XL.
Pulsar Evolution 2200. EXB additional battery module. /AD- Page 11. Connect the two supports for the upright position. 2.6 Connection to the data-line protection port (optional). Transfer to battery power.
Threshold for the low-battery warning. Function. Battery tab. Sensitivity tab. Troubleshooting requiring MGE UPS SYSTEMS after-sales support.
Troubleshooting not requiring MGE UPS SYSTEMS after-sales support (all versions). 4.1 Trouble-shooting.
Installation of the new battery module. Battery Replacement Chart.
Simplified diagram. Pulsar Evolution 2200. Pulsar Evolution 3000 XL + 3 EXB. Pulsar Evolution 3000.
MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1-800-438-7373 www.mgeups.com IMPORTANT SAFETY INSTRUCTIONS Read before installing product SAVE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the utmost care.
We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar Evolution a reference in environmental protection include: The eco-designapproach used in product development, recycling of Pulsar Evolution at the end of its service life. To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar Evolution range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. This manual contains important instructions for Pulsar Evolution Models that must be followed during installation, operation and maintenance of the UPS and batteries.
The Pulsar Evolution UPS Models that are covered in this manual are listed below. Pulsar Evolution 2200, 3000, 3000XL The normal battery voltage for all models is as follows: Pulsar Evolution 2200-72V, 3000-72V The Pulsar Evolution UPS is intended for installation in a temperature within 0 to 40º C, free of conductive contaminant’s. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Introduction CAUTION: Safety of persons The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-powersource.
Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA by checking their characteristics (maximum leakage current of the UPS = 2 mA). The battery supplied with the UPS contains small amounts of toxic materials.
![Mge Mge](http://images10.okr.ro/serve/auctions.v7/2013/oct/27/e6904a28036d95bab5298af07be9e388-7102710-700_700.jpg)
To avoid accidents, the directives listed below must be observed: - Never burn the battery (risk of explosion). Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). Comply with all applicable regulations for the disposal of the battery. Batteries constitute a danger (electrical shock, burns). The short-circuitcurrent may be very high.
Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles. Do not lay tools or metal parts on top of batteries. CAUTION: Product safety The UPS connection instructions and operation described in the manual must be followed in the indicated order. UPS must be connected to a nearby wall outlet that is easily accessible.
The UPS can be disconnected from the AC-powersource by removing the power cord. Check that the indications on the rating plate correspond to your AC-powersystem and to the actual electrical consumption of all the equipment to be connected to the UPS. Never install the UPS near liquids or in an excessively damp environment. Never let a foreign body penetrate inside the UPS.
Never block the ventilation grates of the UPS. Never expose the UPS to direct sunlight or source of heat. If the UPS must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is -25ºCto +55ºC. Special precautions All handling operations will require at least two people (unpacking, installation in rack system).
Once installed and connected to the AC power source for the first time, the battery will start to charge. Full charging to obtain the rated battery backup time requires at least 8 hours. Before and after the installation, if the UPS remains de-energizedfor a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25°C). This charges the battery, thus avoiding possible irreversible damage. During the replacement of the battery module, it is imperative to use the same type and number of element previously mounted in the UPS, in order to maintain an identical level of performance and safety.
In case of doubt, don’t hesitate to contact our after sales department (for more information, refer to the web site www.mgeups.com). Foreword Using this document Information may be found in two ways, using: the contents; the index. Pictograms IMPORTANT: Important instructions that must always be followed. NOTE: Information, advice, help. WARNING: Indicates present eminent danger, precautionary action required.
CAUTION: Indicates to proceed with caution, precautionary action required. Visual indication. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED flashing. Presentation 1.1 Overall view. 7 Tower position.
7 Rack position. 7 1.2 Back. 8 1.3 Control panel. Installation 2.1 Unpacking and parts check. 10 2.2 Upright installation (tower position). 11 2.3 Flat installation (rack position).
12 2.4 Connecting the protected equipment. 13 2.5 Connection to the RS232 or USB communications port (optional). 14 2.6 Connection to the data-lineprotection port (optional). 14 2.7 Installation of the communications-cardoption. Operation 3.1 Start-up.
16 3.2 Shift to booster or fader mode (during voltage variations in the AC-input power). 16 3.3 Operation on battery power (following failure of AC-input power). 17 Transfer to battery power. 17 Threshold for the low-batterywarning.
17 3.4 Personalization (optional). 18 Function. 18 ON / OFF conditions tab. 18 Battery tab. 18 Voltage-thresholdstab.
19 Sensitivity tab. Maintenance 4.1 Trouble-shooting. 20 4.2 Replacement of the battery module. Appendices 6.1 Technical data. 24 Simplified diagram. 24 Technical characteristics. 25 Examples of battery backup times.
26 6.2 Glossary. 27 6.3 Index. Presentation 1.2 Back Pulsar Evolution 2200 Data line protection 1 IN 1 34Z5 U.P.S. Ble RS232 ramma Prog OUT 2 SITE WIRING 2 AC Input FAULT WARNING AC Input Volt 120V1O ble TO BATTERY 3 battery cabinets max Amps 16A MAX 72Vdc, 7Ah AC Output Volt 120V1O ramma BATTERY CONNECTOR Hertz 50/60 Hz CABINET 344-50282-00 Volt: 72Vdc 40A Hertz 50/60 Hz g W/VA 1540W/1920VA o U.S.
6,094,363 Pr AC Output 5-20P 1 2 3 5 4 6 8 9 10 Pulsar Evolution 3000 / 3000 XL Data line protection A 1 IN elb 1 A 34Z5 U.P.S. RS232 B amma Progr OUT 2 SITE WIRING WARNING 1/2 2 AC Input FAULT 3 battery cabinets B max for 3000 12 battery cabinets AC Input Volt 120V1O e 344-50297-00 max for 3000XL Volt: 72Vdc 40A Amps 24A MAX bl 000W/2800VA for 3000 ammarg 72Vdc, 9Ah BATTERY CONNECTOR AC Output Hertz 50/60 Hz TO BATTERY Only for 3000 H Ve olrt tz 5 10 2/6 0V0 Hz 1O CABINET U.S. 6,094,363 W/VA 22000W/2568VA for 3000 XL Pro AC Output L5-30 5-30 P 1 2 3 5 4 6 7 8 9 10 EXB additional battery module 11 3 11 13. 1 USB communications port. 2 RS232 communications port.
3 Connector for automatic detection of an additional battery module. 4 Data-lineprotection. 5 Slot for communications-cardoption. 6 Connector for an additional battery module.
7 Output circuit breakers. 8 Six receptacles for direct connection of protected equipment. 9 Two programmable receptacles (1 and 2).
10 Input power cords for connection to AC-powersource; 2200/5-20Pand 3000/L5-30. 11 Battery module connectors (to the UPS or to other battery modules). 12 Connectors for automatic detection of additional battery modules.
13 Circuit breaker for battery ON/OFF and protection. Installation 2.1 Unpacking and parts check 26 25 27 28 29 30 31 P U L S A R Evolution 3 0 0 0 32 26 RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order, for free, the following part number: 66090 27 USB communications cable.
28 Telescopic rails for mounting in 19' bay with mounting hardware. 29 Two securing systems for equipment power cords. 30 CD-ROMwith the Solution-Pacand UPS Driver software. 31 Product documentation. 32 Two supports for the upright position. 1 - Remove the power cord supplying the equipment to be protected. Pulsar Evolution 2200/3000/3000 XL: Connect the supplied input power cord 10 to the AC power wall receptacle.
360 ° 2 - Connect the protected equipment to the 9 UPS using the rotation power cord 25. It Rotation Plug is advised to connect priority loads to the 8 four standard receptacles 8 and any non- priority loads to the two programmable receptacles 9. If the UPS is connected to a com- puter running MGE communica- tions software, it is possible to pro- 29 gram the interruption of power to the programmable receptacles 9 during operation on battery power, thus reserving backup power for the priority loads.
25 3 - Lock the connections using the securing 10 system 29. As soon as the UPS is energized, the battery begins charging. Eight hours are required to charge to the full rated back- up time.
![Mge Pulsar Evolution 2200 Software Developer Mge Pulsar Evolution 2200 Software Developer](https://www.pcexpansion.es/img/img_prod/pcexpansion/Eaton%20Warranty%20.jpg)
Operation 3.4 Personalization (optional) Function Personalization parameters can be set and modified using the UPS Driver software installed on a computer that is connected to the UPS (see section 2.5 Connection to the RS232 or USB communications port). Check that the RS232 26 communications cable is connected.
UPS Driver installation: 1 - Insert the Solution-Pac CD-ROMcontaining the UPS Driver software in the drive of a PC running Windows. 2 - Open the Windows File manager or Explorer and select the CD-ROMdrive. 3 - Double-click' Emb Evolutio Config Setup.exe'.